MH12 N95 Mask Features
Technical Data on MH12 N95 Masks
- Tested for conformity with NIOSH N95 Criteria for filter efficiency (Equivalent to FFP2, EN 149-2001 + A1: 2009) by ITS Lab
- Combines comfort, leak-free fit, filtration efficiency, and breathability
- Leakage (IS 9473: 2002 A3): Passed
- Carbon dioxide content of inhalation air (IS 9473: 2002 A6): Passed
- Breathing resistance (IS 9473: 2002 A3): Passed
- Splash resistance (ASTM F1862:07): Passed
- Filtration efficiency (%) (NIOSH standard): Passed (>95%)
Testing and Certifications
- Tested by ITS Laboratory, Noida (U.P) as per the standards NIOSH & IS:9473:2002 (The test reports are available here for downloading)
- Research testing inputs and data from TIFR, BARC, and DRDE (DRDO) during the development stage.
- Application for BIS Certification is in progress
Ownership
- Knowhow: Venture Center (on behalf of Pune Masks Action Group)
- Trademark: Venture Center (on behalf of Pune Masks Action Group)
- Machinery and equipment: Ultra Autosonic India